Comparison of Standards of Olfactometry
Presented to EE-6 Odor Committee
at AWMA 1999 Annual Meeting, St. Louis, MO

prEN 13725
(Sept. 1999 DRAFT) †‡

ASTM E-679-91

A&WMA EE-6

Requirements

          

Dynamic Dilution

wpe1.gif (978 bytes)

wpe1.gif (978 bytes)

wpe1.gif (978 bytes)

Triangular Forced-Choice

wpe1.gif (978 bytes)*

wpe1.gif (978 bytes)

wpe1.gif (978 bytes)

Ascending Concentration Series

wpe1.gif (978 bytes)

wpe1.gif (978 bytes)

wpe1.gif (978 bytes)

Odor Free Dilution Air

wpe1.gif (978 bytes)

wpe1.gif (978 bytes)

wpe1.gif (978 bytes)

Presentation Flow Rate (lpm)

20

- - -

8

Presentation Face Velocity (m/s)

0.2 - 0.5

- - -

0.02 - 0.05

Presentation Mask Diameter (cm)

3 - 5

- - -

6 - 10

Maximum Lower Dilution Ratio

2^7

- - -

2^3

Minimum Upper Dilution Ratio

2^14

- - -

2^13

Dilution Ratio Range

2^13

- - -

- - -

Dilution Factor Between Levels

1.4 - 2.4

2.0 or 3.0

2

Includes Sampling Requirements

wpe1.gif (978 bytes)

   

wpe1.gif (978 bytes)

Includes Olfactometer Performance Criteria

wpe1.gif (978 bytes)

       

Includes Assessor Performance Criteria

wpe1.gif (978 bytes)

       

†  This standard will supersede NVN 2820 (Netherlands), VDI 3881 (Germany) and all other European Standards.
‡  Australia & New Zealand have drafted an equivalent standard.

*  The CEN Draft also allows Binary Forced Choice, Yes/No Procedures, and Forced Choice Probability Methods.